A Comparison of Special Bonding Techniques for Transmission and Distribution Cables

2020

In this paper, a review of the existing special bonding techniques for medium voltage (MV) and high-voltage (HV) cables is presented. Special bonding techniques have the purpose of reducing sheath currents, thereby limiting copper losses and the reduction of the ampacity of cables. The authors present a literature review to identify various bonding techniques and how these have evolved over the years thanks to new technologies. Simulations of the most used techniques have been performed in Matlab/Simulink, to compare their strengths and drawbacks.

Computer scienceLimitingspecial bonding techniquesCurrent transformerCross bondingSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaTransmission (telecommunications)Electromagnetic coilreactance bondingElectronic engineeringsheath bonding transformersAmpacityReduction (mathematics)MATLABcomputerVoltagecomputer.programming_language
researchProduct

Experimental investigation on PLC signal crossing of power transformers

2014

In this work the use of PLC in MV-LV networks is investigated, by means of experimental tests in the case of a two-ways MV/LV communication between two secondary substations. The two substations are connected by a MV overhead power line. Moreover each substation has a by-pass connection at MV bus-bars and a MV/LV power transformer. A ST7580 transceiver is used to inject the communication signal. The transceiver is embedded in a new interface device developed by the authors. In the paper the communication issues are introduced and some experimental tests are presented and discussed. Such tests have been carried out in the presence of voltage net, i.e. 24 kV, with the aim to verify the possib…

EngineeringElectric power distributionbusiness.industrycommunication systems power system communication power transformers communication equipment testing narrow band power line communication attenuation smart gridsOverhead power lineElectrical engineeringcommunication systemsnarrow band power line communicationSignalCurrent transformerpower transformerspower system communicationElectric power transmissionsmart gridsElectronic engineeringPower engineeringTransceiverbusinessSettore ING-INF/07 - Misure Elettriche E Elettronicheattenuationcommunication equipment testingVoltage
researchProduct

A novel approach to current transformer characterization in the presence of harmonic distortion

2009

The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…

EngineeringFrequency responseElectric current measurementAcousticsElectric transformer testingErrorsElectric utilitiesOperation conditionsHarmonic distortionPower companiesHarmonic analysisElectric power transmission networksFrequency responsePower electronicsWaveformMetering modeCurrent transformer (CT)Electrical and Electronic EngineeringInstrumentationNon-sinusoidal currentsPiezoelectric transducersTotal harmonic distortionbusiness.industryElectric power distributioncurrent transformer frequency response harmonic distortion power system harmonics transducersCurrent transformerRatio errorsTransducerElectric instrument transformersHarmonicPower system harmonicsCurrent (fluid)businessPower transmissionSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveforms
researchProduct

A DC current transformer for large bandwidth and high common-mode rejection

1999

A review of known magnetic-coupled current-sensing techniques is presented, Subsequently, a novel technique is introduced, based on a configuration discussed in a previous paper. The previous technique made use of a galvanomagnetic device (Hall effect sensor) to sense the magnetization of a current transformer core, so that the sum of the Hall voltage and the voltage across the secondary shunt resistor would yield a faithful copy of the input current. The technique described in this paper makes use of the same principle to obtain a high bandwidth (from DC to 1 MHz) and very high common-mode rejection current transformer, without the need for a Hall effect probe. This is achieved by subtract…

EngineeringIsolation transformerbusiness.industryLinear variable differential transformerFlyback transformerElectrical engineeringDistribution transformerCurrent transformerControl and Systems EngineeringAutotransformerElectronic engineeringEnergy efficient transformerElectrical and Electronic EngineeringbusinessDelta-wye transformerIEEE Transactions on Industrial Electronics
researchProduct

A portable instrument for the location and identification of defects generating PD

2011

A portable instrument based on an antenna probe and suitable for partial discharge detection, have been characterized through both laboratory and on-site experiments carried out on coils and stator windings of ac rotating machines. The antenna probe allows the capture of electromagnetic waves in a bandwidth of 0.1–100 MHz. Pulse signals and ac supply voltage reference are obtained by means of high-pass and low-pass filters, respectively, so avoiding the need of a direct connection with the objects under test. By this way, real-time phase resolved partial discharge patterns can be derived. Results of a comparison of the diagnostic information provided by PD patterns due to conducted and irra…

EngineeringPartial Discharges; Insulation Systems; Rotating Machines; DiagnosticsRotating Machinebusiness.industryStatorAcousticsLow-pass filterPartial DischargesBandwidth (signal processing)Electrical engineeringCurrent transformerlaw.inventionInsulation SystemsInsulation SystemSettore ING-IND/31 - ElettrotecnicaRotating MachinesElectromagnetic coillawPartial dischargePartial DischargeHigh-pass filterbusinessDiagnosticsDiagnostics FPGA Partial Discharges SensorsVoltage reference
researchProduct

The impact of fixed and moving scatterers on the statistics of MIMO vehicle-to-vehicle channels

2021

©2009 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. Article also available from publisher: http://dx.doi.org/10.1109/VETECS.2009.5073879 In this paper, we study the impact of fixed and moving clusters of scatterers on the statistics of multiple- input multiple-output (MIMO) vehicle-to-vehicle (V2V) channels. Double-bounce scattering is assumed for fixed scatterers, while single-bounce scattering is considered fo…

EngineeringScatteringbusiness.industryAutocorrelationMIMOFunction (mathematics)Space (mathematics)Vehicle-to-vehicleExpression (mathematics)Current transformerStatisticsVDP::Technology: 500::Information and communication technology: 550::Telecommunication: 552businessComputer Science::Information Theory
researchProduct

PMSM Drives Sensorless Position Control with Signal Injection and Neural Filtering

2009

Vector Field Oriented Control (FOC) is one of the best control methods for high-dynamic electrical drives. To avoid the adoption of the speed/position sensor (resolver/encoder), a sensorless technique should be used. Among the various sensorless methods in literature, those based on machine saliency detection by signal injection seem to be most useful for thier giving the possibility of closing the position control loop. This paper proposes a method for enhancing both rotating and pulsating voltage carrier injection methods by a neural adaptive band filter. Results show the goodness of the proposed solution.

EngineeringSignal processingVector controlArtificial neural networkbusiness.industryFilter (signal processing)neural networksCurrent transformerControl theoryResolverElectronic engineeringPMSMsensorless controlbusinesssignal processingEncoderPosition sensor
researchProduct

Rogowski coil current transducer compensation method for harmonic active power error

2015

Abstract In the harmonic active power measurement, the highest uncertainties are generally introduced by the current and voltage transducers. In a previous paper, the authors showed that the current transformer (CT) can introduce significant errors in such measurement, especially if the phase shift between voltage and current is close to ±90°. In such condition the errors on harmonic power measurement are mainly due to the CT phase displacement. This paper shows that better results can be achieved with more linear transducers, such as the Rogowski coil current transducers (RCCTs), whose metrological performance in distorted condition can be improved, by means of a proper compensation method…

Frequency responseEngineeringbusiness.industryApplied MathematicsAcousticsPower system harmonics Transducers Current transformers. Frequency response Power measurement Rogowski coilTransducersElectrical engineeringAC powerCondensed Matter PhysicsCurrent transformerRogowski coilCompensation (engineering)Power (physics)Current transformersFrequency responseHarmonicPower system harmonicsElectrical and Electronic EngineeringPower measurementbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheRogowski coilVoltage
researchProduct

Characterization of clamp-on current transformers under nonsinusoidal conditions

2009

This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…

Frequency responseMaterials scienceElectric current measurementTransductorAcousticsErrorsTransducersPhase (waves)Energy Engineering and Power TechnologyClamp-on current transformers current transformers (CTs) frequency response power system harmonics transducers.Power transformersDistributed power generationElectric power systemsHarmonic analysisElectric power transmission networksClamp-on current transformersCurrent transformersFrequency responsePower electronicsFrequency measurementElectronic engineeringElectrical and Electronic EngineeringElectrical conductorTomographyComputed tomographyElectric power distributionElectric transformersCircuit faultsFault currentsFundamental frequencyComputerized tomographyFourier seriesCurrent measurementCurrent transformerDiagnostic radiographyElectric instrument transformersElectric frequency measurementPower system harmonicsMedical imagingCurrent transformers (CTs)Air gap (plumbing)Power transmissionElectric network analysisExcitation
researchProduct

Frequency response of Measurement Current Transformers

2008

In this paper the frequency response of two CTs is experimentally evaluated in the range of 30-600 Hz. A theoretical analysis of CTs behavior has been developed by means of the equivalent circuit. It was shown, by an experimental test, that, for the frequency range analyzed, the transformer equivalent circuit is a valid tool for the evaluation of CT performances.

Frequency responseTotal harmonic distortionMaterials scienceTransducerlawPower system harmonicsElectronic engineeringEquivalent circuitIec standardsTransformerCurrent transformerHardware_LOGICDESIGNlaw.invention2008 IEEE Instrumentation and Measurement Technology Conference
researchProduct